The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Climate and Energy Use in Glazed Spaces

Author

Summary, in English

Glazed spaces ranging from small glazed verandas to large atrium buildings have become a common feature in architecture. A glazed space is greatly affected by aspects of the outside climate such as insolation and temperature. In the design of such spaces, more sophisticated design tools are therefore required in order to estimate the climate inside the glazed space and the energy requirements for heating and cooling than in the design of ordinary buildings.



One object has been to elucidate the relationship between building design and the climate, thermal comfort and energy requirements in different types of glazed spaces. Another object has been to study the effect of the glazed space on energy requirements in adjacent buildings. It has also been the object to develop a simple calculation method for the assessment of temperatures and energy requirements in glazed spaces.



The research work has mainly comprised case studies of existing buildings with glazed spaces and energy balance calculations using both the developed steady-state method and a dynamic building energy simulation program. Parameters such as the geometry of the building, type of glazing, orientation, thermal inertia, airtightness, ventilation system and sunshades have been studied. These parameters are of different importance for each specific type of glazed space. In addition, the significance of each of these parameters varies for different types of glazed spaces.



The developed calculation method estimates the minimum and mean temperature in glazed spaces and the energy requirements for heating and cooling. The effect of the glazed space on the energy requirements of the surrounding buildings can also be estimated. It is intended that the method should be applied during the preliminary design stage so that the effect which the design of the building will have on climate and energy requirement may be determined. The method may provide an insight into how glazed spaces behave with regard to climate and energy.

Department/s

Publishing year

1996

Language

English

Publication/Series

Rapport TABK

Document type

Dissertation

Publisher

Building Science

Topic

  • Building Technologies

Keywords

  • Byggnadsteknik
  • Building construction
  • design tool
  • field measurements
  • calculations
  • thermal comfort
  • cooling
  • heating
  • energy requirement
  • solar energy
  • climate
  • atrium buildings
  • glazed spaces

Status

Published

Supervisor

  • [unknown] [unknown]

ISBN/ISSN/Other

  • ISSN: 1103-4467
  • ISRN: LUTADL/TABK--1009--SE

Defence date

22 November 1996

Defence time

09:15

Defence place

Sölvegatan 24, A-sektionen, hörsal C

Opponent

  • Anne Grete Hestnes (Professor)