Oxygen measurement by multimode diode lasers employing gas correlation spectroscopy
Author
Summary, in English
Multimode diode laser (MDL)-based correlation spectroscopy (COSPEC) was used to measure oxygen in ambient air, thereby employing a diode laser (DL) having an emission spectrum that overlaps the oxygen absorption lines of the A band. A sensitivity of 700 ppm m was achieved with good accuracy (2%) and linearity (R-2 = 0.999). For comparison, measurements of ambient oxygen were also performed by tunable DL absorption spectroscopy (TDLAS) technique employing a vertical cavity surface emitting laser. We demonstrate that, despite slightly degraded sensitivity, the MDL-based COSPEC-based oxygen sensor has the advantages of high stability, low cost, ease-of-use, and relaxed requirements in component selection and instrument buildup compared with the TDLAS-based instrument. (C) 2009 Optical Society of America
Department/s
Publishing year
2009
Language
English
Pages
990-997
Publication/Series
Applied Optics
Volume
48
Issue
5
Document type
Journal article
Publisher
Optical Society of America
Topic
- Atom and Molecular Physics and Optics
Status
Published
ISBN/ISSN/Other
- ISSN: 2155-3165