The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Sequential GC/MS analysis of sialic acids, monosaccharides, and amino acids of glycoproteins on a single sample as heptafluorobutyrate derivatives

Author

  • A Pons
  • C Richet
  • C Robbe
  • Annkatrin Herrmann
  • P Timmerman
  • G Huet
  • Y Leroy
  • Ingemar Carlstedt
  • C Capon
  • JP Zanetta

Summary, in English

A GUMS procedure was developed for the analysis of all major constituents of glycoproteins. The rationale for this approach is that by using GC/MS analysis of the constituents as heptafluorobutyrate derivatives, it was possible to quantitatively determine the sialic acid, monosaccharide, fatty acids (when present), and the amino acid composition with the sample remaining in the same reaction vessel during the entire procedure. A mild acid hydrolysis was used to liberate sialic acids and was followed by formation of methyl-esters of heptafluorobutyrate (HFB) derivatives. After GC/MS analysis of sialic acids, the remaining material was submitted to acid-catalyzed methanolysis followed by the formation of HFB derivatives. After GUMS analysis of the monosaccharides, the sample was supplemented with norleucine (as internal standard) and hydrolyzed with 6 M HCl followed by the formation of isoamyl-esters of HFB derivatives and GC/MS analysis. His and Trp residues were modified during the step of acid-catalyzed methanolysis, but the resulting derivatives were stable during acid hydrolysis and quantitatively recovered by GUMS analysis. As a result, all constituents of glycoproteins (sialic acids, monosaccharides (or di- and trisaccharides) and amino acids) are identified in the electron impact mode of ionization and quantified using three GUMS analysis in the same chromatographic conditions and using a limited number of reagents, a considerable advantage over previous techniques. This method is very sensitive, all data (qualitative and quantitative) being obtained at the sub-nanomolar level of initial material.

Publishing year

2003

Language

English

Pages

8342-8353

Publication/Series

Biochemistry

Volume

42

Issue

27

Document type

Journal article

Publisher

The American Chemical Society (ACS)

Topic

  • Biochemistry and Molecular Biology

Status

Published

ISBN/ISSN/Other

  • ISSN: 0006-2960