Gradient echo-based quantitative MRI of human brain at 7T : Mapping of T1, MT saturation and local flip angle

Author

  • Hampus Olsson

Summary, in English

Quantitative MRI (qMRI) refers to the process of deriving maps of MR contrast parameters, such as relaxation times, from conventional images. If the qMRI maps have a high degree of precision and a low degree of bias, they can be compared longitudinally, across subjects, and (ideally) between measurement protocols and research sites. They also provide a more direct biophysical interpretation of the pixel intensities.
The increased magnetization of spins at ultra-high field (UHF) strengths of 7T and above could potentially be translated into higher spatial resolution and/or reduced scan time. This thesis tackles UHF-related challenges in qMRI, namely the increased inhomogeneity of the radio frequency (RF) field (B1) and increased specific absorption rate (SAR). The changing relaxation times (i.e. prolonged T1 and shortened T2) also needs to be accounted for.
Here, spoiled gradient-recalled echo (GRE) techniques are employed to map (primarily) two structural MR parameters, i.e. the longitudinal relaxation time (T1) and the magnetization transfer (MT) saturation (MTsat). Because of its influence at UHF, emphasis is also put on mapping of the local flip angle. Primarily, qMRI is performed by the inversion of analytical signal equations, as opposed to numerical approaches.
The process of implementing and modifying the dual flip angle (DFA) technique in conjunction with an MT-weighted GRE for 7T is described. Implementation is performed within the well-established multi-parameter mapping (MPM) framework and special attention is afforded to the reduction of biases as well as overcoming saftey restrictions imposed by SAR. An approach to obtain high-SNR low-bias flip angle maps at 7T, using the dual refocusing echo acquisition mode (DREAM) technique is also presented. This is important since high fidelity flip angle maps are a prerequisite in DFA-based T1-mapping and recommended for correcting MTsat at UHF. Furthermore, MPRAGE-based techniques are discussed. Firstly, it is demonstrated how to most effectively obtain B1-corrected MPRAGE images of “pure” T1 contrast using a sequential protocol This is followed by a description of T1-mapping using MP2RAGE. Finally, an innovative technique for simultaneous mapping of T1 and the local flip angle is introduced, dubbed “MP3RAGE”.

Publishing year

2021-10-05

Language

English

Document type

Dissertation

Publisher

Media-Tryck, Lund University, Sweden

Topic

  • Other Physics Topics

Keywords

  • MR studies; magnetic resonance (MR)
  • 7 Tesla
  • T1 mapping
  • magnetization transfer saturation
  • Flip angle mapping
  • spoiled gradient echo
  • MR studies; magnetic resonance (MR)
  • 7T
  • T1 mapping
  • magnetization transfer saturation
  • Flip angle mapping
  • spoiled gradient echo

Status

Published

Project

  • Gradient echo-based quantitative MRI of human brain at 7T

Supervisor

ISBN/ISSN/Other

  • ISBN: 978-91-7895-965-5
  • ISBN: 978-91-7895-966-2

Defence date

29 October 2021

Defence time

09:00

Defence place

Lundmarksalen, Astronomihuset. Join via zoom: https://www.msf.lu.se/evenemang/disputation-hampus-olsson

Opponent

  • Gisela Hagberg (Fil. Dr.)