High temperature waveguide measurements of the permittivity and permeability
Author
Summary, in English
This paper describes a setup for measurements of the permittivity and the permeability at temperatures
from room temperature up to 1000 °C using a single rectangular waveguide. The hardware design of the setup
that can handle these temperatures is developed and described. Measurements on a NiZn ferrite sample are
performed in order to evaluate the performance of the setup and the procedure that is used to determine the
permittivity and permeability from the measured S-parameters.
from room temperature up to 1000 °C using a single rectangular waveguide. The hardware design of the setup
that can handle these temperatures is developed and described. Measurements on a NiZn ferrite sample are
performed in order to evaluate the performance of the setup and the procedure that is used to determine the
permittivity and permeability from the measured S-parameters.