The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Analysis of regulatory phosphorylation sites in ZAP-70 by capillary high-performance liquid chromatography coupled to electrospray ionization or matrix-assisted laser desorption ionization time-of-flight mass spectrometry

Author

Summary, in English

A methodology for the rapid and quantitative analysis of phosphorylation sites in proteins is presented. The coupling of capillary high-performance liquid chromatography (HPLC) to electrospray ionization mass spectrometry (ESI-MS) allowed one to distinguish phosphorylation sites based on retention time and mass difference from complex peptide mixtures. The methodology was first evaluated and validated for a mixture of non-, mono-, and dityrosine-phosphorylated synthetic peptides, corresponding to the tryptic fragment 485-496 (ALGADDSYYTAR) of the human protein tyrosine kinase ZAP-70. The limits of detection for the non-, mono- and diphosphorylated peptides were about 15. 40 and 100 fmol, respectively, when using a 300 mum I.D. column. Application of the method was extended to identify phosphopeptides generated from a trypsin digest of recombinant autophosphorylated ZAP-70, in particular with respect to quantifying the status at the regulatory phosphorylation sites Tyr-492 and Tyr-493. Combination of chromatographic and on-line tandem mass spectrometry data, allowed one to ascertain the identity of the detected peptides, a prerequisite to analyses in more complex biological samples. As an extension to the methodology described above, we evaluated the feasibility of interfacing capillary HPLC to matrix assisted laser desorption ionisation time-of-Right mass spectrometry (MALDI-TOF-MS), using a micromachined piezoelectric flow-through dispenser as the interface. This enabled direct arraying of chromatographically separated components onto a target plate that was precoated with matrix for subsequent analysis by MALDI-TOF-MS without further sample handling. (C) 2001 Elsevier Science B.V. All rights reserved.

Publishing year

2001

Language

English

Pages

323-334

Publication/Series

Journal of Chromatography. B, Biomedical Sciences and Applications

Volume

752

Issue

2

Document type

Journal article

Publisher

Elsevier

Topic

  • Analytical Chemistry
  • Medical Engineering

Keywords

  • phosphorylation
  • ZAP-70
  • PROTEIN-PHOSPHORYLATION
  • TRIFLUOROACETIC-ACID
  • COMPLEX-MIXTURES
  • TYROSINE KINASE
  • IDENTIFICATION
  • ACTIVATION
  • PEPTIDES
  • ONLINE

Status

Published

ISBN/ISSN/Other

  • ISSN: 1387-2273