Cone beam CT for QA of synthetic CT in MRI only for prostate patients

Author

Summary, in English

Purpose: Magnetic resonance imaging (MRI)-only radiotherapy is performed without computed tomography (CT). A synthetic CT (sCT) is used for treatment planning. The aim of this study was to develop a clinically feasible quality assurance (QA) procedure for sCT using the kV-cone beam CT (CBCT), in an MRI-only workflow for prostate cancer patients. Material and method: Three criteria were addressed; stability in Hounsfield Units (HUs), deviations in HUs between the CT and CBCT, and validation of the QA procedure. For the two first criteria, weekly phantom measurements were performed. For the third criteria, sCT, CT, and CBCT for ten patients were used. Treatment plans were created based on the sCT (MriPlannerTM). CT and CBCT images were registered to the sCT. The treatment plan was copied to the CT and CBCT and recalculated. Dose–volume histogram (DVH) metrics were used to evaluate dosimetric differences between the sCT plan and the recalculated CT and CBCT plans. HU distributions in sCT, CT, and CBCT were compared. Well-defined errors were introduced in the sCT for one patient to evaluate efficacy of the QA procedure. Results: The kV-CBCT system was stable in HU over time (standard deviation <40 HU). Variation in HUs between CT and CBCT was <60 HU. The differences between sCT–CT and sCT–CBCT dose distributions were below or equal to 1.0%. The highest mean dose difference for the CT and CBCT dose distribution was 0.6%. No statistically significant difference was found between total mean dose deviations from recalculated CT and CBCT plans, except for femoral head. Comparing HU distributions, the CBCT appeared to be similar to the CT. All introduced errors were identified by the proposed QA procedure, except all tissue compartments assigned as water. Conclusion: The results in this study shows that CBCT can be used as a clinically feasible QA procedure for MRI-only radiotherapy of prostate cancer patients.

Department/s

Publishing year

2018-11

Language

English

Pages

44-52

Publication/Series

Journal of Applied Clinical Medical Physics

Volume

19

Issue

6

Document type

Journal article

Publisher

American College of Medical Physics

Topic

  • Radiology and Medical Imaging

Keywords

  • cone beam CT
  • MRI, MRI only
  • prostate cancer
  • quality assurance
  • synthetic CT

Status

Published

Research group

  • Medical Radiation Physics, Malmö

ISBN/ISSN/Other

  • ISSN: 1526-9914