Author

  • Sami Väänänen
  • Hanna Isaksson
  • Petro Julkunen
  • Joonas Sirola
  • Heikki Kröger
  • Jukka Jurvelin

Summary, in English

Measurement of bone mineral density (BMD) by DXA (dual-energy X-ray absorptiometry) is generally considered to be the clinical golden standard technique to diagnose osteoporosis. However, BMD alone is only a moderate predictor of fracture risk. Finite element analyses of bone mechanics can contribute to a more accurate prediction of fracture risk. In this study, we applied a method to estimate the 3D geometrical shape of bone based on a 2D BMD image and a femur shape template. Proximal femurs of eighteen human cadavers were imaged with computed tomography (CT) and divided into two groups. Image data from the first group (N = 9) were applied to create a shape template by using the general Procrustes analysis and thin plate splines. This template was then applied to estimate the shape of the femurs in the second group (N = 9), using the 2D BMD image projected from the CT image, and the geometrical errors of the shape estimation method were evaluated. Finally, finite element analysis with stance loading condition was conducted based on the original CT and the estimated geometrical shape to evaluate the effect of the geometrical errors on the outcome of the simulations. The volumetric errors induced by the shape estimation method itself were low (<0.6%). Increasing the number of bone specimens used for the template decreased the geometrical errors. When nine bones were used for the template, the mean distance difference (±SD) between the estimated and the CT shape surfaces was 1.2 ± 0.3 mm, indicating that the method was feasible for estimating the shape of the proximal femur. Small errors in geometry led systematically to larger errors in the mechanical simulations. The method could provide more information of the mechanical characteristics of bone based on 2D BMD radiography and could ultimately lead to more sensitive diagnosis of osteoporosis.

Publishing year

2011

Language

English

Pages

529-538

Publication/Series

Biomechanics and Modeling in Mechanobiology

Volume

10

Issue

4

Document type

Journal article

Publisher

Springer

Topic

  • Orthopedics

Status

Published

ISBN/ISSN/Other

  • ISSN: 1617-7940