On the Improvement of the Poor Heat Transfer Lee-Side Regions of Square Cross-Section Ribbed Channels.

Author

Summary, in English

Heat transfer and flow characteristics of six ribbed channels of square cross section having different rib structure are computed with the objective of improving heat transfer in the lee-side of the ribs. Six ribs are installed on the bottom walls of each channel. The rib pitch-to-height ratio (P/e) is 10. Details of the turbulent flow structure, temperature fields, local heat transfer coefficients, flow friction coefficients, normalized heat transfer rates, and normalized friction factors are reported. The simulations use the v(2)f turbulence model and inlet Reynolds number range of 8,000 to 24,000. A uniform heat flux is appropriately applied on all surfaces. The heat transfer performances features of the ribbed channels of various designs are evaluated and compared. A case with an inclined lee-side structure having an inclination angle of 160 degrees yields the highest Nusselt number and friction factor, about 4.6%-6.4% higher than those with rectangular ribs, and 7.1%-9.0% higher heat transfer when the heated-surface area is considered. Increased pressure drop is kept within certain limits when considering the balance between cooling effectiveness and pressure loss for the comparisons. Though having the best heat transfer, the case with the inclined back-wall geometry of the ribs does not present the better overall thermal performance due to the higher friction. The heat transfer enhancement is more prominent when improvements of the poor heat transfer regions downstream of the rib are computed with the surface area change excluded. A conclusion to be drawn is that lee-side improvement of heat transfer can be effected with suitable design of the rib downstream side. This finding can be applied to improvement of turbine airfoil cooling.

Department/s

Publishing year

2014

Language

English

Pages

963-989

Publication/Series

Numerical Heat Transfer Part A: Applications

Volume

66

Issue

9

Document type

Journal article

Publisher

Taylor & Francis

Topic

  • Energy Engineering

Status

Published

ISBN/ISSN/Other

  • ISSN: 1040-7782