The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Extracorporeal whole-blood immunoadsorption enhances radioimmunotargeting of iodine-125-labeled BR96-biotin monoclonal antibody

Author

Summary, in English

This study investigates the efficacy of tumor radioimmunotargeting with 125I-labeled BR96-biotin monoclonal antibody using a new method, whole-blood immunoadsorption (WBIA), based on direct adsorption of unbound monoclonal antibody (MAb) from blood without preceding separation of plasma. METHODS: Highly tumor-reactive, internalizing, chimeric BR96 MAb of isotype IgG1 binds to a tumor-associated Lewis-type (Le(Y)) cell surface antigen. Forty-six Brown Norwegian male rats were inoculated intramuscularly and beneath the liver or kidney capsule with syngeneic rat colon carcinoma BN7005, expressing Lewis-type antigen, and investigated. The rats were injected intravenously with 3.5-4.5 MBq 125I-labeled BR96-biotin. Twenty of the rats underwent WBIA starting 5 or 12 hr after injection. About six blood volumes were passed through an avidin-gel adsorption column during 2 hr. RESULTS: By using WBIA, whole-body radioactivity was reduced by 50%, and plasma activity by 85%. Both directly after completion of WBIA and 33 hr later, the activity uptake in tumors manifested only a nonsignificant decrease as compared with corresponding controls (p > 0.05) and had approximately similar time-activity curves. Uptake ratios for tumor (T):bone marrow, T:liver, T:kidney and T:lung were enhanced 2.3- to 3.5-fold in all three tumor models, as compared with controls. The ratio of liver tumor to bone marrow was improved from 10:1 to 30:1. CONCLUSION: This new method of WBIA yields significantly improved radioimmunotargeting of highly tumor-reactive, internalizing MAb BR96.

Publishing year

1997

Language

English

Pages

895-901

Publication/Series

Journal of Nuclear Medicine

Volume

38

Issue

6

Document type

Journal article

Publisher

Society of Nuclear Medicine

Topic

  • Radiology, Nuclear Medicine and Medical Imaging

Keywords

  • tumor
  • rat
  • radioimmunotargeting
  • MAb BR96
  • immunoadsorption

Status

Published

ISBN/ISSN/Other

  • ISSN: 0161-5505