The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Time dependence of the activity concentration ratio of red marrow to blood and implications for red marrow dosimetry.

Author

Summary, in English

BACKGROUND: The method for red marrow dosimetry in radioimmunotherapy, in the absence of specific activity uptake in red marrow, is based on the activity measured in the blood or plasma. The activity concentration ratio of red marrow to blood is then assumed to be constant. The aim of the current study was to determine whether this ratio varies with time after injection. METHODS: Measurements were carried out with both animals and patients.Tumor-bearing rats were intravenously injected with iodine-131-, iodine-125-, indium-111-, or rhenium-188-labeled BR96, a chimeric immunoglobulin G1 monoclonal antibody. (All were chelate-labeled, except for iodine-131, which was iodogen-labeled.) Measurements were made of the activity concentration in blood and bone marrow at different points in time after injection, and the ratio of activity concentration in red marrow and blood as a function of time postinjection (RMBLR[t)]) was calculated. For patients treated with iodine-131-labeled monoclonal antibody (LL2, Immunomedics Inc., Morris Plains, NJ; anti-CD22; immunoglobulin G2 isotype of mouse origin), blood samples were drawn and scintillation camera images taken at different times after injection. The red marrow activity concentration in the sacrum was determined by activity quantification from regions of interest. The activity concentration in blood was also measured. The RMBLR(t) was calculated based on these data. RESULTS: For both patients and rats, the RMBLR(t) was increased 72 hours after injection. Furthermore, it was found that the use of a constant RMBLR can lead to an over- or underestimation of the absorbed dose in bone marrow. CONCLUSIONS: These data demonstrate the difficulty in using fixed values of the activity concentration ratio of red marrow to blood for dosimetry.

Publishing year

2002

Language

English

Pages

1235-1239

Publication/Series

Cancer

Volume

94

Issue

4 Suppl

Document type

Journal article

Publisher

John Wiley & Sons Inc.

Topic

  • Cancer and Oncology

Keywords

  • Animal
  • Bone Marrow/*metabolism
  • Dose-Response Relationship
  • Radiation
  • Human
  • Models
  • Radiation Dosage
  • Radioisotopes/*blood/metabolism
  • Radioimmunotherapy/*methods
  • Radiometry/methods
  • Rats
  • Non-U.S. Gov't
  • Time Factors
  • Support

Status

Published

ISBN/ISSN/Other

  • ISSN: 1097-0142