The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Axillary recurrence rate after negative sentinel node biopsy in breast cancer - Three-year follow-up of the Swedish Multicenter Cohort Study

Author

  • Leif Bergkvist
  • Jana de Boniface
  • Per-Ebbe Jönsson
  • Christian Ingvar
  • Göran Liljegren
  • Jan Frisell

Summary, in English

Background: Sentinel lymph node biopsy is an established staging method in early breast cancer. After a negative biopsy, most institutions will not perform a completion axillary dissection. The present study reports the current axillary recurrence (AR) rate, overall and disease-free survival in the Swedish Multicenter Cohort Study. Methods: From 3534 patients with primary breast cancer <= 3 cm prospectively enrolled in the Swedish multicenter cohort study, 2246 with a negative sentinel node biopsy and no further axillary surgery were selected. Follow-up consisted of annual clinical examination and mammography. Twenty-six hospitals and 131 surgeons contributed to patient accrual. Results: After a median follow-up time of 37 months (0-75), the axilla was the sole initial site of recurrence in 13 patients (13 of 2246, 0.6%). In another 7 patients, axillary relapse occurred after or concurrently with a local recurrence in the breast, and in a further 7 cases, it coincided with distant or extra-axillary lymphatic metastases. Thus, a total of 27 ARs were identified (27 of 2246, 1.2%). The overall 5-year survival was 91.6% and disease-free survival 92.1%. Conclusions: This is the first report from a national multicenter study that covers, not only highly specialized institutions but also small community hospitals with just a few procedures per year. Despite this heterogeneous background, the results lie well within the range of AR rates published internationally (0%-3.6%). The sentinel node biopsy procedure seems to be safe in a multicenter setting. Nevertheless, long-term follow-up data should be awaited before firm conclusions are drawn.

Publishing year

2008

Language

English

Pages

150-156

Publication/Series

Annals of Surgery

Volume

247

Issue

1

Document type

Journal article

Publisher

Lippincott Williams & Wilkins

Topic

  • Surgery

Status

Published

Research group

  • Surgery

ISBN/ISSN/Other

  • ISSN: 1528-1140