The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Atrial flutter and atrial tachycardia detection using Bayesian approach with high resolution time-frequency spectrum from ECG recordings

Author

  • Jinseok Lee
  • David D. McManus
  • Peter Bourrell
  • Leif Sörnmo
  • Ki H. Chon

Summary, in English

Contemporary methods of atrial flutter (AFL), atrial tachycardia (AT), and atrial fibrillation (AF) monitoring, although superior to the standard 12-lead ECG and symptom-based monitoring, are unable to accurately discriminate between AF, AFL and AT. Thus, there is a need to develop accurate, automated, and comprehensive atrial arrhythmia detection algorithms using standard ECG recorders. To this end, we have developed a sensitive and real-time realizable algorithm for accurate AFL and AT detection using any standard electrocardiographic recording. Our novel method for automatic detection of atrial flutter and atrial tachycardia uses a Bayesian approach followed by a high resolution time-frequency spectrum. We find the TQ interval of the electrocardiogram (ECG) corresponding to atrial activity by using a particle filter (PF), and analyze the atrial activity with a high resolution time-frequency spectral method: variable frequency complex demodulation (VFCDM). The rationale for using a high-resolution time-frequency algorithm is that our approach tracks the time-varying fundamental frequency of atrial activity, where AT is within 2.0-4.0 Hz, AFL is within 4.0-5.3 Hz and NSR is found at frequencies less than 2.0 Hz. For classifications of AFL (n = 22), AT (n = 10) and normal sinus rhythms (NSR) (n = 29), we found that our approach resulted in accuracies of 0.89, 0.87 and 0.91, respectively; the overall accuracy was 0.88. (C) 2013 Elsevier Ltd. All rights reserved.

Publishing year

2013

Language

English

Pages

992-999

Publication/Series

Biomedical Signal Processing and Control

Volume

8

Issue

6

Document type

Journal article

Publisher

Elsevier

Topic

  • Electrical Engineering, Electronic Engineering, Information Engineering

Keywords

  • Atrial flutter
  • Atrial tachycardia
  • Particle filter
  • Dynamic ECG model
  • High resolution time-frequency spectrum
  • Variable frequency complex
  • demodulation
  • Electrocardiogram

Status

Published

ISBN/ISSN/Other

  • ISSN: 1746-8094