The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Levels of bacterial endotoxin in air of animal houses determined with the use of gas chromatography - Mass spectrometry and Limulus test

Author

  • Dorota Pomorska
  • Lennart Larsson
  • Czeslawa Skorska
  • Jolanta Sitkowska
  • Jacek Dutkiewicz

Summary, in English

Air samples were collected on glass fibre filters in 22 animal houses and 3 hay storage barns and examined for the presence of bacterial endotoxin with the Limulus (LAL) test and the gas chromatography - tandem mass spectrometry (GC-MSMS) technique, based on detection of 3-hydroxy fatty acids (3-OH-FAs) as chemical markers of the endotoxin lipopolysaccharide. The median concentrations of airborne endotoxin determined with LAL test in poultry houses, sheep sheds, piggeries, cow barns, and horse stables were respectively 62.49 mu g/m(3), 26.2 mu g/m(3), 3.8 mu g/m(3), 1.65 mu g/m(3), and 1. 14 mu g/m(3), while those determined with the GC-MSMS technique were respectively 1.06 mu g/m(3), 7.91 mu g/m(3), 0.2 mu g/m(3), 0.31 mu g/m(3), and 1.42 mu g/m(3). The median concentrations of airborne endotoxin determined with LAL test and GC-MSMS technique in hay storage barns were much smaller, 0.09 mu g/m(3) and 0.03 mu g/m(3), respectively. The concentrations of airborne endotoxin (LPS) detected with GC-MSMS method in the air of sheep sheds were significantly greater than in all other examined facilities, while those detected in hay storage barns were significantly smaller than in all other examined facilities (p<0.05). The concentrations of airborne endotoxin determined with LAL test and GC-MSMS analysis exceeded in most of animal houses examined (91% by each method) the threshold limit value for airborne endotoxin of 0.1 mu g/m(3) proposed by various authors. A significant correlation (p<0.05) between the concentrations of endotoxin determined with the LAL and GC-MSMS techniques was found in the air samples collected in poultry houses and sheep sheds, but not in other examined facilities. 3-OH FAs with C-14-C-18 chains were predominant in the air of the facilities under study. A significant correlation (p<0.05) was found between the concentrations of endotoxin determined with LAL test and the amounts of 3-OH FAs with C-14-C-16 chains. In conclusion, endotoxin in the concentrations detected in this study may present a respiratory hazard to both humans and livestock animals.

Publishing year

2007

Language

English

Pages

291-298

Publication/Series

Annals of Agricultural and Environmental Medicine

Volume

14

Issue

2

Document type

Journal article

Publisher

Institute of Agricultural Medicine in Lublin, Poland

Topic

  • Microbiology in the medical area

Keywords

  • 3-hydroxy fatty acids
  • Limulus test
  • spectrometry
  • mass
  • gas chromatography
  • animal houses
  • air
  • endotoxin
  • organic dust

Status

Published

ISBN/ISSN/Other

  • ISSN: 1898-2263