Circadian variation in human cerebrospinal fluid production measured by magnetic resonance imaging
Author
Summary, in English
Recent advances in magnetic resonance imaging have made it possible to visualize and quantify flow of cerebrospinal fluid (CSF) in the brain. The net flow of CSF through the cerebral aqueduct was used to measure CSF production in six normal volunteers at different times during a 24-h period. CSF production varied greatly both intra- and interindividually. The average CSF production in each time interval showed a clear tendency to circadian variation, with a minimum production 30% of maximum values (12 +/- 7 ml/h) approximately 1800 h and a nightly peak production approximately 0200 h of 42 +/- 2 ml/h. The total CSF production during the whole 24-h period, calculated as an average of all measurements, was 650 ml for the whole group and 630 ml for repeated measurements in each time interval in one of the volunteers.
Department/s
- Diagnostic Radiology, (Lund)
- Drug Target Discovery
Publishing year
1992
Language
English
Pages
20-24
Publication/Series
American Journal of Physiology: Regulatory, Integrative and Comparative Physiology
Volume
262
Issue
1
Document type
Journal article
Publisher
American Physiological Society
Topic
- Radiology, Nuclear Medicine and Medical Imaging
- Pharmacology and Toxicology
Status
Published
Research group
- Drug Target Discovery
ISBN/ISSN/Other
- ISSN: 1522-1490