The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

A novel respirometer for online detection of metabolites in aquaculture research: Evaluation and first applications

Author

  • Kevin Torben Stiller
  • Damian Moran
  • Klaus Heinrich Vanselow
  • Kai Marxen
  • Sven Wuertz
  • Carsten Schulz

Summary, in English

In this study we describe a novel flow-through respirometer with automated and semi-continuous detection of key water variables. The recirculating aquaculture system was designed to house aquatic organisms in culture-like conditions and allow long-term, high-precision measurements. Nine respirometry tanks (250 L in volume each) housed animals, and a tenth (without animals) acted as a reference tank. A single measurement unit made sequential measurements of each tank to eliminate the problem of sensor variation associated with multi-probe setups. The accuracy of the analyzers in relation to measurement range was: O-2 = 1%; CO2 < 1%; NH3 = 2%; temperature <= 0.25%; and pH +/- 0.01. Dissolved CO2 was measured using air-water equilibration coupled with non-dispersive infrared detection of carrier gas, and NH3 was quantified using a reagent-based assay and spectophotometric autoanalyzer. Though expensive and not common in aquaculture or physiology research, these two automated metabolite analyzers could operate in both fresh and seawater, and offered high precision and accuracy. We report on the performance of these instruments for aquaculture research in two trials using a freshwater (rainbow trout, Oncorhynchus mykiss) and seawater fish species (turbot, Scophthalmus maximus). One of the main constraints imposed by the sequential measurement of multiple tanks was the measurement frequency of each tank. In the aforementioned system, NH3 analyzes took the longest (12 min), followed by CO2 (7 min), O-2 (6 min), and pH (3 mm). (C) 2013 Elsevier B.V. All rights reserved.

Department/s

Publishing year

2013

Language

English

Pages

23-31

Publication/Series

Aquacultural Engineering

Volume

55

Document type

Journal article

Publisher

Elsevier

Topic

  • Zoology

Keywords

  • Ammonia
  • Carbon dioxide
  • Oxygen
  • Respirometry
  • Recirculating aquaculture
  • system
  • Washout effect

Status

Published

ISBN/ISSN/Other

  • ISSN: 1873-5614