Performance of a Personal Low-Weight Aerosol Sampler with Particle Size Fractionation and Time Resolution

Author

Summary, in English

A low-weight aerosol sampler has been developed and tested. Internal losses for both sub-micron and

large particles ( < 10 tam) are of the order of 5 %. The size fractionation patterns indicate that the sampler may be

used to collect a separate respirable fraction in good agreement with the BMRC standard and a coarse fraction

deternuned by the inlet design.

Publishing year

1983

Language

English

Pages

409-413

Publication/Series

Journal of Aerosol Science

Volume

14

Issue

3

Document type

Conference paper

Topic

  • Environmental Health and Occupational Health

Keywords

  • aerosol sampler
  • size fractionation
  • time resolution

Conference name

The Tenth Annual Conference of the Association for Aerosol Research

Conference date

1982-10-14 - 1982-10-17

Conference place

Bologna, Italy

Status

Published