A description is given of the upgraded photon tagging facility at the MAX IV Laboratory. Two magnetic spectrometers are used to momentum analyze post-bremsstrahlung electrons. The tagged photon range extends from 10 to 180 MeV with an energy resolution of about 300 keV. The system has been operated at rates up to 4 x 10(6) photons s(-1) MeV (-1). Different diagnostic tools are described as well as the experimental program.