The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Thorium exposure during tungsten inert gas welding with thoriated tungsten electrodes

Author

Summary, in English

The exposure to Th-232 from TIG welding with thoriated electrodes has been determined at five different workshops. Welding with both alternating and direct current was investigated. The exposure levels of Th-232 were generally below 10 mBq m(-3) in the breathing zone of the welders. Two samples from AC welding showed significant higher exposure levels, probably due to maladjustment of the TIG welding power source. Samples of the respirable fraction of Th-232 from grinding thoriated electrodes were also collected showing exposure levels of 5 mBq m(-3) or lower. A dose estimate has been made for two scenarios, one realistic and one with conservative assumptions, showing that the annual committed effective dose from inhalation of Th-232, Th-230, Th-228 and Ra-228, for a full-time TIG welder, in the realistic case is below 0.3 mSv and with conservative assumptions around 1 mSv or lower. The contribution from grinding electrodes was lower, 10 muSv or lower in the realistic case and 63 muSv or lower based on conservative assumptions. The study does not exclude occurrence of higher exposure levels under welding conditions different from those prevailing in this study.

Publishing year

2003

Language

English

Pages

349-357

Publication/Series

Radiation Protection Dosimetry

Volume

103

Issue

4

Document type

Journal article

Publisher

Oxford University Press

Topic

  • Radiology, Nuclear Medicine and Medical Imaging

Status

Published

ISBN/ISSN/Other

  • ISSN: 1742-3406