The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Harmful azo colorants in leather. Determination based on their cleavage and extraction of corresponding carcinogenic aromatic amines using modern extraction techniques.

Author

  • Cecilia Sparr Eskilsson
  • Richard Davidsson
  • Lennart Mathiasson

Summary, in English

This study concerns the possibilities of using microwave-assisted extraction (MAE) or supercritical fluid extraction (SFE) for detection of harmful azo colorants in leather. After degreasing of the leather sample with SFE there follows a reductive cleavage of the azo colorants to their corresponding aromatic amines in the MAE or SFE equipment. The aromatic amines are subsequently extracted using either MAE or SFE and then finally determined by liquid chromatography with diode-array detection. The results have been compared with recoveries obtained using the German DIN method 53316. This standard method, based on conventional solvent extraction, is used in several European countries. Overall much better recoveries were obtained using MAE or SFE. With both MAE and SFE the amine recoveries of spiked leather samples were generally above 50%. The average recoveries were 62% for MAE and 60% for SFE (solvent collection) compared to 24% with the DIN method. For genuine leather samples the recoveries decreased, especially for benzidine. In this case the average values for MAE, SFE and DIN were 54, 38 and 19%, respectively. The quantification limits in leather samples using MAE or SFE were below 1 mg/kg for all amines investigated. The within-laboratory precision was generally better than 10%, varying somewhat with the analyte considered. With the proposed methodology, the amount of hazardous organic solvents used could be decreased and the sample throughput increased with at least a factor of two with less manual handling compared to the DIN method.

Publishing year

2002

Language

English

Pages

215-227

Publication/Series

Journal of Chromatography A

Volume

955

Issue

2

Document type

Journal article

Publisher

Elsevier

Topic

  • Analytical Chemistry

Keywords

  • Azo dyes
  • aromatic
  • Amines

Status

Published

ISBN/ISSN/Other

  • ISSN: 0021-9673