The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Normal limits for left ventricular ejection fraction and volumes determined by gated single photon emission computed tomography - a comparison between two quantification methods

Author

  • Milan Lomsky
  • Lena Johansson
  • Peter Gjertsson
  • Jonas Björk
  • Lars Edenbrandt

Summary, in English

To compare gender-related normal limits for left ventricular (LV) ejection fraction (EF), end-diastolic and end-systolic volumes (EDV and ESV), obtained using two myocardial perfusion-gated single photon emission computed tomography (SPECT) quantification methods. A total of 185 patients were retrospectively selected from a consecutive series of patients examined for coronary artery disease (CAD) or for management of known CAD. Patients were included in the study group if they had normal or probably normal results with stress and rest perfusion imaging and if the combined interpretation of perfusion studies and gated rest studies showed no signs or suspicion of myocardial infarction. The gated SPECT studies were performed using a 2-day stress/gated rest Tc-99m sestamibi protocol. All patient studies were processed using CAFU and quantitative-gated SPECT (QGS), the two software packages for quantification of gated SPECT images. The lower normal limits for EF were higher for CAFU compared with QGS for both women (59% versus 53%) and men (54% versus 47%). The upper normal limits for EDV were also higher for CAFU compared with QGS for both women (133 versus 107 ml) and men (182 versus 161 ml). The differences between the software packages were small for ESV (women 44 versus 44 ml; men 69 versus 74 ml). Gender-specific normal limits need to be applied for LV EF and volumes determined by gated SPECT. Separate criteria for abnormal LV EF and EDV need to be used for women and men depending on the software package used.

Publishing year

2008

Language

English

Pages

169-173

Publication/Series

Clinical Physiology and Functional Imaging

Volume

28

Issue

3

Document type

Journal article

Publisher

John Wiley & Sons Inc.

Topic

  • Physiology

Keywords

  • radionuclide imaging
  • heart function tests
  • computer-assisted
  • gender
  • reference values

Status

Published

Research group

  • Nuclear medicine, Malmö

ISBN/ISSN/Other

  • ISSN: 1475-0961