A comparison between flexible electrogoniometers, inclinometers and three-dimensional video analysis system for recording neck movement

Author

  • Leticia Carnaz
  • Cristiane S. Moriguchi
  • Ana Beatriz de Oliveira
  • Paulo R. P. Santiago
  • Glauco A. P. Caurin
  • Gert-Åke Hansson
  • Helenice J. C. Gil Coury

Summary, in English

This study compared neck range of movement recording using three different methods goniometers (EGM), inclinometers (INC) and a three-dimensional video analysis system (IMG) in simultaneous and synchronized data collection. Twelve females performed neck flexion-extension, lateral flexion, rotation and circumduction. The differences between EGM, INC, and IMG were calculated sample by sample. For flexion-extension movement, IMG underestimated the amplitude by 13%; moreover, EGM showed a crosstalk of about 20% for lateral flexion and rotation axes. In lateral flexion movement, all systems showed similar amplitude and the inter-system differences were moderate (4-7%). For rotation movement, EGM showed a high crosstalk (13%) for flexion-extension axis. During the circumduction movement, IMG underestimated the amplitude of flexion-extension movements by about 11%, and the inter-system differences were high (about 17%) except for INC-IMG regarding lateral flexion (7%) and EGM-INC regarding flexion-extension (10%). For application in workplace, INC presents good results compared to IMG and EGM though INC cannot record rotation. EGM should be improved in order to reduce its crosstalk errors and allow recording of the full neck range of movement. Due to non-optimal positioning of the cameras for recording flexion-extension, IMG underestimated the amplitude of these movements. (C) 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

Publishing year

2013

Language

English

Pages

1629-1637

Publication/Series

Medical Engineering & Physics

Volume

35

Issue

11

Document type

Journal article

Publisher

Elsevier

Topic

  • Environmental Health and Occupational Health

Keywords

  • Neck pain
  • Movement
  • Range of motion
  • Workplace
  • Goniometer
  • Kinematics

Status

Published

ISBN/ISSN/Other

  • ISSN: 1873-4030