The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Generation of hexahydrophthalic anhydride atmospheres in a controlled human-use test chamber

Author

  • Bo A Jönsson
  • Hans Welinder
  • Gunnar Skarping

Summary, in English

A method for generating controlled atmospheres of hexahydrophthalic anhydride (HHPA) in an 8 m3 exposure chamber was developed. The permeation principle was used for gaseous HHPA generation. HHPA concentration was monitored by sampling on XAD-2 tubes and by a Fourier-transform infrared (FTIR) spectrometer using the partial least-square quantitative method. The repeatability of the FTIR was 5%, the reproducibility 12%, and the limit of detection 10 micrograms/m3. A bubbler method determined the sum of HHPA and HHP acid by using gas chromatography/mass spectrometry detection after derivatization with methanol/boron trifluoride. The precision of the work-up procedure was 3% and the recovery was 94% at 300 ng sampled amount of HHPA. The limit of detection was 10 ng HHPA. The variation in the permeation rate was 3% over 3 days. Different concentrations in the exposure chamber were generated by changing the temperature of the permeation tubes. The generated HHPA concentration range, at human exposure, was 3-90 micrograms/m3. The concentration at one temperature was reproducible even after major changes in the temperature. The coefficient of variation (CV) of six samples from different places in the breathing zone was 3%. The variation in the concentration, during an 8-hour human exposure at 10 micrograms/m3, was 3%. Time-weighted averages (8 hour) for human exposures of 10 micrograms/m3 (CV = 15%; n = 6); 37 micrograms/m3 (CV = 5%; n = 5); and 81 micrograms/m3 (CV = 6%; n = 9) were obtained at intended concentrations of 10 micrograms/m3, 40 micrograms/m3, and 80 micrograms/m3. The loss of HHPA in the exposure chamber was 54% (CV = 17%).(ABSTRACT TRUNCATED AT 250 WORDS)

Publishing year

1994

Language

English

Pages

330-338

Publication/Series

American Industrial Hygiene Association Journal

Volume

55

Issue

4

Document type

Journal article

Publisher

Taylor & Francis

Topic

  • Environmental Health and Occupational Health

Status

Published

ISBN/ISSN/Other

  • ISSN: 1542-8117