The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Improved performance characteristics of the von Willebrand factor ristocetin cofactor activity assay using a novel automated assay protocol.

Author

Summary, in English

Summary Background, objectives and methods: An accurate, sensitive and precise assay for reliable determination of the ristocetin cofactor activity of von Willebrand factor (VWF:RCo) in plasma and von Willebrand Factor (VWF)-containing concentrates has been evaluated. The assay is based on a commercially available automated protocol with modifications including a combination of adding additional ristocetin and the use of two calibration curves for the high and low measuring ranges. Results: Addition of extra ristocetin resulted in improved measurement of VWF recoveries from various VWF-containing concentrates that were underestimated using the standard automated protocol. The modifications resulted in improved assay performance over an extended measuring range (2.00 - 0.03 IU/mL). Accuracy was tested using VWF deficiency plasma spiked with 1(st) international standard for VWF concentrate. Seven dilutions, ranging between 1.80 and 0.05 IU/mL, were analyzed and resulted in measured concentrations between 80% and 100% of the assigned potency of the standard. Linearity was determined from the regression plot of the same concentrate dilutions and resulted in a correlation coefficient of 0.998. The repeatability, expressed as coefficient of variation, was 2% in the normal range (0.90 IU/mL) and 8% at the level of 0.05 IU/mL. The corresponding reproducibility results were 2% and 15% at the normal and low measuring ranges, respectively. Conclusions: Analysis of patients with von Willebrand disease indicates that the modified automated BCS((R)) protocol has a superior discrimination power compared with the standard protocol. This is especially true in samples with low VWF, as in patients with type 3 von Willebrand disease.

Publishing year

2010

Language

English

Pages

2216-2223

Publication/Series

Journal of Thrombosis and Haemostasis

Volume

8

Document type

Journal article

Publisher

Wiley-Blackwell

Topic

  • Cardiac and Cardiovascular Systems

Status

Published

Research group

  • Clinical Chemistry, Malmö

ISBN/ISSN/Other

  • ISSN: 1538-7933